Cardiac mechano-electric feedback and arrhythmias

Peter Kohl

Cardiac mechano-electric feedback and arrhythmias

from pipette to patient

by Peter Kohl

  • 2 Want to read
  • 29 Currently reading

Published by W.B. Saunders in Philadelphia, PA .
Written in English

    Subjects:
  • Heart -- Contraction,
  • Arrhythmia,
  • Heart conduction system,
  • Biological control systems

  • Edition Notes

    Includes bibliographical references and index.

    StatementPeter Kohl, Frederick Sachs, Michael R. Franz.
    ContributionsSachs, Frederick., Franz, M. R. 1949-
    Classifications
    LC ClassificationsQP113.2 .K64 2005
    The Physical Object
    Paginationxxi, 423 p., [12] p. of plates :
    Number of Pages423
    ID Numbers
    Open LibraryOL23823567M
    ISBN 101416000348
    LC Control Number2004065902

    Rapid advancements in cardiac electrophysiology require today's health care scientists and practitioners to stay up to date with new information both at the bench and at the fully revised 7th Edition of Cardiac Electrophysiology: From Cell to Bedside, by Drs. Douglas Zipes, Jose Jalife, and William Stevenson, provides the comprehensive, multidisciplinary coverage you need.   Rapid advancements in cardiac electrophysiology require today's health care scientists and practitioners to stay up to date with new information both at the bench and at the fully revised 7th Edition of Cardiac Electrophysiology: From Cell to Bedside, by Drs. Douglas Zipes, Jose Jalife, and William Stevenson, provides the comprehensive, multidisciplinary coverage you need Format: Book.

    Cardiac “mechanotransduction” involves various physiological and biophysical phenomena in which mechanical energy is transduced to changes in function of cardiac myocytes and of the whole heart. In this chapter different manifestations of mechanotransduction are reviewed, with special emphasis on the “mechano-electric” feedback by: 2. Mechanosensitive channels, mechanosensitive ion channels or stretch-gated ion channels (not to be confused with mechanoreceptors).They are present in the membranes of organisms from the three domains of life: bacteria, archaea, and eukarya. They are the sensors for a number of systems including the senses of touch, hearing and balance, as well as participating in cardiovascular regulation and.

    Rapid advancements in cardiac electrophysiology require today’s health care scientists and practitioners to stay up to date with new information both at the bench and at the fully revised 7th Edition of Cardiac Electrophysiology: From Cell to Bedside, by Drs. Douglas Zipes, Jose Jalife, and William Stevenson, provides the comprehensive, multidisciplinary coverage you need. Rhythmicity patterns were consistent with expectation from a coupled oscillator model (interacting cardiac and respiratory rhythms) of mechano-electric feedback. Mechano-electric feedback experiments with small mammals are challenging but doable (Huang et al., ), and provide diverse opportunities to probe with drugs (Fabritz, ), with Cited by:


Share this book
You might also like

International Comparative Education

Training aids for dam safety

The great California deserts.

Export of frigate engines to Iraq

An occult view of the war

Training for mental health

Photo of the Tall Man

Water-quality, biological, and habitat assessment of the Boeuf River basin, southeastern Arkansas, 1994-96

corporate new wave

Promoting the flow of information on labour relations and labour laws in ASEAN.

Nissen hut in war and peace.

Whitewater canoeing

Cardiac mechano-electric feedback and arrhythmias by Peter Kohl Download PDF EPUB FB2

Numerous clinical evidences as well as experimental studies show an increased vulnerability to atrial arrhythmias by acute stretch of the atrial walls. However, the mechanism by which atrial dilatation favours the development of sustained atrial tachyarrhythmias, such as atrial fibrillation (AF), is not fully understood.

The effects of acute atrial dilatation on the substrate of atrial Cited by: 3. Foreword: stretching our views of cardiac control / Peter M. Spooner --Preface: cardiac mechano-electric feedback: from pipette to patient / Peter Kohl, Frederick Sachs and Michael R.

Franz --Sect. (Sub-cellular) mechanisms of cardiac mechano-electric feedback   Cardiac Mechano-Electric Feedback and Arrhythmias by Michael R. Franz,available at Book Depository with free delivery worldwide.

Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of cardiac mechano-electrical coverage ranges from stretch-activated ion channels to mechanically induced arrhythmias and mechanical interventions for heart rhythm by: Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of cardiac mechano-electrical coupling.

Its coverage ranges from stretch-activated ion channels to mechanically induced arrhythmias and mechanical interventions for heart rhythm correction. Cardiac Mechano-Electric Coupling and Arrhythmias Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of cardiac mechano-electrical l books Cardiac Mechano-Electric Coupling and Arrhythmias.

The events relating stretch of heart muscle to cardiac arrhythmias that have evolved over the years since mechano-electric feedback was first discerned are summarised in Fig. Evidence from the heart in situ and from isolated cardiac tissue and cells indicates that acute stress activates mechano-electrical coupling thereby opening stretch Cited by: Book Description.

Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of cardiac mechano-electrical coupling.

Its coverage ranges from stretch-activated ion channels to mechanically induced arrhythmias and mechanical interventions for. Mechano-electric feedback in right atrial tissue from animals with cardiac hypertrophy after infarction and human atria Whilst myocardial infarction (MI) is a regional pathology, it can lead to alterations in global hemodynamic load of the heart, thereby inducing cardiac by: 8.

ISBN: OCLC Number: Notes: Revised edition of: Cardiac mechano-electric feedback and arrhythmias. Description. Cardiac Mechano-Electric Coupling and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of cardiac mechano-electrical coupling.

Its coverage ranges from stretch-activated ion channels to mechanically induced arrhythmias and mechanical interventions for heart rhythm s: 1. Read "Cardiac Mechano-Electric Coupling and Arrhythmias" by available from Rakuten Kobo. The information provided carefully highlights both consensus insight and current shortcomings in our understanding of cardiac mechano-electric coupling.

The book has been thoroughly revised and expanded since publication of the first edition in Brand: OUP Oxford. Book Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and 'Read more.

Introduction. Mechano-electrical feedback (MEF) within heart tissue has been identified many decades ago as a phenomenon describing electrophysiological changes in response to myocardial stretch ().As evidence for MEF grew, so did its recognition as a possible mechanism of cardiac arrhythmias (Franz, ).However, despite its potential importance, MEF has received relatively little Cited by: Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of.

A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text. The intracardiac pathway that leads from changes in the cardiac mechanical environment to altered electrical activity is referred to as mechano-electric feedback (MEF).

Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of cardiac mechano-electrical coverage ranges from stretch-activated ion channels to mechanically induced arrhythmias and mechanical interventions for heart rhythm correction.

Commotio cordis (Latin, "agitation of the heart") is an often lethal disruption of heart rhythm that occurs as a result of a blow to the area directly over the heart (the precordial region) at a critical time during the cycle of a heart beat, producing what is termed an R-on-T phenomenon that leads to the is a form of ventricular fibrillation (V-Fib), not mechanical damage to the Specialty: Emergency medicine.

BOOK REVIEW BOOK REVIEW BOYDEN, PENELOPE A. CARDIAC MECHANO‐ELECTRIC FEEDBACK AND ARRHYTHMIAS FROM PIPETTE TO PATIENT, edited by Peter Kohl, Frederick Sachs, and Michael Franz, Elsevier Saunders (), Hardbound, pages, Imprint: Saunder, $, ISBN: 1‐‐‐8.

Have you ever had a thought that seems. Discover Book Depository's huge selection of Frederick Sachs books online. Free delivery worldwide on over 20 million titles.Cooper PJ, Kohl P. Mechanical modulation of sino-atrial node pacemaking.

In: Kohl P, Franz MR, Sachs F, editors. Cardiac mechano-electric feedback and arrhythmias: from pipette to patient. 1 st ed. Philadelphia, Elsevier Saunders. ;72– Google ScholarCited by: 4. Cardiac Mechano-Electric Feedback and Arrhythmias offers a thoroughly reviewed compendium written by leading experts in the field on the mechanism and consequences of cardiac mechano-electrical coupling.

Its coverage ranges from stretch-activated ion channels to mechanically induced arrhythmias and mechanical Author: David Brackett.